CASE52 · Manufacturing · Compressor staging

Testing the required compressor count with loading and unloading data

Ten-second power, airflow, pressure and operating-state records distinguish useful air production from unloaded running. Stepwise dispatch tests seek efficient base/trim combinations while preserving production pressure.

01 · CASE ANALYSIS

Why running status is insufficient

A compressor can consume electricity while producing little useful air in an unloaded state. Counting running units alone can therefore hide avoidable power.

Large and smaller compressors were analyzed together to separate base-load supply from demand-following trim operation.

02 · CASE ANALYSIS

Align the core measurements

Collect compressor kW, CDA airflow, supply/header pressure, load factor, active units and loading/unloading on one time axis.

Compare system specific energy, electricity divided by delivered air volume. When using kW divided by Nm³/h, the resulting unit is kWh/Nm³; source shorthand must not obscure the time basis.

Separate operating states
StateData to examineDiagnostic meaning
LoadingkW, airflow, pressure and load factorUseful production and specific energy
UnloadingResidual kW, duration and repeated eventsUnloaded-energy loss
StoppedStop duration and next startRequired unit count and transitions

03 · CASE ANALYSIS

Diagnose transitions and storage

Separate loading, unloading and stopped intervals. Identify additional starts, whether flow actually increased, and how long the added machine remained useful.

Receiver capacity, pressure deadband and sequencing may explain why short peaks trigger unnecessary starts. The lowest average unit count is not enough if terminal pressure becomes unstable.

04 · CASE ANALYSIS

Stepwise dispatch test

Record a baseline, change the running combination during a suitable demand interval, allow stabilization and remeasure total compressor power and service conditions.

Remaining machines may consume more power after one unit stops. Calculate savings from system measurements rather than the stopped unit’s nameplate kW.

Baseline versus test
IndicatorBaselineChanged dispatch
Active unitsRecordAdjust and record
Airflow and header/terminal pressureMeasureMeasure
Total compressor powerMeasureMeasure
Loading/unloading durationRecordRecord
System specific energyCalculateCalculate
Production conditionsConfirm normalConfirm maintained

05 · CASE ANALYSIS

Verification and transfer

Use comparable airflow, pressure and production conditions or an adjusted baseline where adequate data exist. Establish efficient base/trim roles from actual curves rather than machine size alone.

The source documents field analysis and Test & Adjust logic but does not publish an isolated final saving rate for this case.