CASE22 · Manufacturing · Blast-furnace blowers

Diagnosing blast-furnace blower intensity, pressure and IGV operation

Seasonal blower data separate equipment differences from weather effects. Pressure margins, duct losses and unusual IGV readings are investigated while avoiding an unsupported filter-efficiency claim.

01 · CASE ANALYSIS

Operating challenge

Annual blower electricity cost was approximately KRW 145 billion. Seasonal airflow changed little, but summer power and intensity increased.

Some blowers showed very low or negative IGV readings despite high load, calling for field checks of signal consistency and control logic. Intake-filter differential pressure did not show a clear correlation with intensity.

02 · CASE ANALYSIS

Data and diagnostic indicators

The comparison used electricity/cost, power, normalized airflow, intensity, load, IGV opening, discharge/furnace-side pressures, duct losses, weather and intake-filter ΔP.

Overall intensity averaged approximately 0.078 kWh/Nm³; unit values ranged from about 0.075 to 0.081. Average power was 33.1 MW per furnace, about 34.8 MW in summer. Summer intensity was approximately 7.2% above winter.

Reported operating observations
IndicatorValue
Overall / unit UPI0.078 / 0.075–0.081 kWh/Nm³
Mean / summer power33.1 / 34.8 MW per furnace
Summer intensity increaseApproximately 7.2% over winter
Mean load / IGV91% / 20%
Mean / lowest duct loss0.13 / 0.09 kg/cm²

03 · CASE ANALYSIS

Operating opportunities

Compare efficient blower conditions under the required blast flow and pressure. Review unnecessary pressure margins only while satisfying furnace operating and safety requirements.

The reported mean supply pressure was approximately 4.3 kg/cm², with some furnaces at 4.5 against a lower group around 4.0. Duct loss averaged 0.13 kg/cm² and reached about 0.09 in the lowest-loss furnace. Verify unusual IGV signals before changing control.

04 · CASE ANALYSIS

Evidence and M&V

The maximum approximately 8.2% unit-intensity spread is not a savings rate. The report does not provide confirmed post-improvement energy or cost savings.

Use production conditions, required blast flow/pressure, ambient temperature and blower combinations in the baseline. A lack of clear filter-ΔP correlation means filter work should not be assigned a quantified benefit without further evidence.

Findings and interpretation
FindingMeaning
Unit intensity spread: approximately 8.2%Benchmark opportunity; not verified saving
Supply pressure: 4.5 versus 4.0 kg/cm² groupsApproximately 11% reported difference; check required pressure
Low or negative IGV valuesCheck signals and actual controls
Filter ΔP versus intensityNo clear correlation established

05 · CASE ANALYSIS

Engineering lesson

Diagnosis includes findings that do not support the initial hypothesis. Record the absence of clear filter correlation and prioritize the better-supported pressure, signal and operating-point investigations.