CASE06 · Manufacturing · Injection, extrusion and utilities

Mapping injection and extrusion electricity with one-minute operating patterns

Individual equipment metering separates production machines from cooling, HVAC and compressed-air loads. One-minute profiles identify priorities after a large year-on-year increase in factory electricity use.

01 · CASE ANALYSIS

Operating challenge

May 2022 factory electricity reached 221,940 kWh compared with 142,704 kWh in May of the previous year, an increase of approximately 55%. Monthly totals alone could not explain which loads caused the increase.

Cooling, HVAC and compressed air were large supporting loads. Machine operation, stopping and standby needed to be compared with auxiliary equipment behavior.

02 · CASE ANALYSIS

Metering and consumption structure

The analysis combined monthly electricity, peak demand and power factor with individual metering of six injection machines, nine extrusion machines and NC equipment. Dedicated chillers, first- and third-floor AHUs, compressors and dust collectors were also measured.

One-minute and 24-hour power profiles were used to compare running, stopping and standby patterns. Average factory load was approximately 298 kW. Process-level shares include associated cooling; end-use shares separate cooling from the production machines.

Process-level average load
ProcessAverage powerShare
Injection, including dedicated cooling59.1 kW19.8%
Extrusion, including dedicated cooling73.0 kW24.5%
HVAC80.8 kW27.1%
Compressed air28.9 kW9.7%
NC equipment—2.0%
Dust collection—4.3%
Office, lighting and other—12.7%

03 · CASE ANALYSIS

Diagnostic priorities

HVAC was the largest single end-use area, making production-linked schedules and setpoints a priority. Injection and extrusion machines needed to be reviewed together with their dedicated cooling.

Compare old and new compressors for concurrent operation, loading/unloading and demand response. Check whether chillers continue running during stopped or low-load production.

04 · CASE ANALYSIS

Evidence and follow-up M&V

This is a measured consumption-structure diagnosis. The report does not state a confirmed savings quantity or financial saving for a specific implemented measure.

After operating or equipment improvements, compare energy under equivalent production conditions and account for operating hours and auxiliary demand. The +55% increase must not be presented as a savings rate.

End-use electricity shares
End useShare
Injection machines14.8%
Extrusion machines20.5%
Dedicated chillers8.9% (26.7 kW)
HVAC27.1%
Compressed air9.7%
NC / dust collection / other2.0% / 4.3% / 12.7%

05 · CASE ANALYSIS

Engineering lesson

Meter production and utility loads on the same time axis. The combination reveals standby and operating interlocks that a factory monthly bill cannot show.